Solution for Seagate ES.2 Hard Drives

Use the feature Fix Capacity Error to recover capacity.

1. PCB 100466725 REV A (DLAJ-4)
2. PCB 100466824 REV A (UJAJ-6)
3. PCB 100466824 REV B (UJAJ-6)
4. PCB 100466824 REV C (UJAJ-6)
5. PCB 100496208 REV A
6. PCB 100504364 REV B
7. PCB 100512588 REV A
8. PCB 100475720 REV A (ZKAJ-7)

 

Hyper Terminal has been locked for these Hard disks and unless you short-circuit two

Pins on  the points shown on Printed Circuit Board, you can not in any manner input

Commands in the terminal window of H D Doctor for Seagate.

 Every time you input command, you will get error message like “LED: 000000CC”.

 

The exact Procedure for this problem.

 

Step 1 Connect the HDD for Seagate to Hard disk and enter terminal mode. (There is 

Need to Remove PCB).

 Press Ctrl + Z, you will get “F3 T>”.

Step 2 Use a tweezers to short-circuit the two red pins. If it succeeds, you will get a

Message like “Invalid   Input Command.”


Step 3 Stop motor in level 2 (F3 2 >Z), and then you can remove tweezers.

Step 4 Reset SMART in level 1 (F3 1>N1) and clear G-List in level T (F3 T>i4, 1, 22).

Step 5 Use the feature Fix Capacity Error to recover capacity.